Title :
Improvements of measuring system on magnetic levitation system for the determination of magnetic flux quantum
Author :
Shiota, F. ; Morokuma, T.
Author_Institution :
Nat. Inst. of Adv. Ind. Sci. & Technol., Japan
Abstract :
A development of a video frame synchronized data sampling system is in progress for superconducting magnetic levitation system parameters to correct an error of vertical displacement reading due to attitude change of floating body using real time movement analysis in equilibrium condition.
Keywords :
constants; magnetic flux; magnetic levitation; equilibrium condition; floating body; magnetic flux quantum; measuring system; real-time movement analysis; superconducting magnetic levitation system; video frame synchronized data sampling system; Counting circuits; Error correction; Frequency synchronization; Influenza; Instruction sets; Magnetic flux; Magnetic levitation; Optical interferometry; Sampling methods; Superconducting magnets;
Conference_Titel :
Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
Conference_Location :
Ottawa, Ontario, Canada
Print_ISBN :
0-7803-7242-5
DOI :
10.1109/CPEM.2002.1034948