• DocumentCode
    2285114
  • Title

    Linking the results of 10 pF capacitance key comparisons CCEM-K4 and EUROMET 345

  • Author

    Delahaye, F. ; Witt, T.J.

  • Author_Institution
    Bur. Int. des Poids et Mesures, Sevres, France
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    526
  • Lastpage
    527
  • Abstract
    We propose a method to link the results of two 10 pF capacitance key comparisons: CCEM-K4 and EUROMET Project 345. The link is made through the results of six linking laboratories who participated in both comparisons. The outcome is two-fold: estimates of the degrees of equivalence with respect to the CCEM key comparison reference value (KCRV) for those laboratories who participated in the EUROMET comparison only, and a matrix giving the bilateral degrees of equivalence for all pairs of laboratories.
  • Keywords
    capacitance measurement; laboratories; measurement standards; 10 pF; CCEM-K4; EUROMET 345; capacitance key comparisons; capacitance standards; degrees of equivalence; linking laboratories; reference value; Capacitance; Databases; Joining processes; Laboratories; Measurement uncertainty; Metrology; Particle measurements; Reproducibility of results; Time measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034954
  • Filename
    1034954