  • Title

    NRC-NIST intercomparison of calibration systems for current transducers with a voltage output at power frequencies

  • Author

    So, E. ; Arseneau, R. ; Bennett, D. ; Nelson, T.L. ; Waltrip, B.C.

  • Author_Institution
    Nat. Res. Council of Canada, Ottawa, Ont., Canada
  • fYear
    2002
  • fDate
    16-21 June 2002
  • Firstpage
    544
  • Abstract
    Summary form only given. A number of international comparisons of current transformer calibrations at power frequencies were conducted in the past. However, all of them were done with a secondary current output of 5 A. This intercomparison of current transformer calibration systems between the National Research Council of Canada and the National Institute of Standards and Technology, USA, is done with a primary current range of 100 A and a secondary output signal of voltage range of 10 V. The comparison is implemented with a transfer standard consisting of a modified commercial current-comparator-based transimpedance with the output voltage adjustable in magnitude and phase within a range of /spl plusmn/1 percent.
  • Keywords
    calibration; current transformers; electric current measurement; transducers; transfer standards; NRC-NIST intercomparison; calibration systems; current comparator-based transimpedance; current transducers; current transformer calibrations; international comparison; power frequencies; transfer standard; voltage output; Calibration; Councils; Current measurement; Current transformers; Frequency; NIST; Power measurement; Sampling methods; Transducers; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements, 2002. Conference Digest 2002 Conference on
  • Conference_Location
    Ottawa, Ontario, Canada
  • Print_ISBN
    0-7803-7242-5
  • Type

    conf

  • DOI
    10.1109/CPEM.2002.1034964
  • Filename
    1034964