DocumentCode :
2293902
Title :
Analytical redundancy for a gas turbine of a combined cycle power plant
Author :
Parra, M. Sánchez ; Verde, C.
Author_Institution :
Inst. de Investigaciones Electricas, Morelos
fYear :
2006
fDate :
14-16 June 2006
Abstract :
This paper studies the structural properties related with the supervision of a gas turbine unit of a combined cycle power plant with sensors faults. The analysis is carried on using the structure defined by constraints and variables contained in a non-linear complex dynamical model. Considering the model described by 37 algebraic and differential equations, the structural analysis based on the matching procedure of the Boolean incidence matrix is used to study the analytical redundancy of the turbine and its redundancy degrees for fault diagnosis. The conclusions obtained with the analysis allows to suggest which sensors and variables have to be considered as the most critical in the turbine from integrity point of view
Keywords :
Boolean algebra; control system analysis; differential equations; fault diagnosis; gas turbines; nonlinear dynamical systems; Boolean incidence matrix; algebraic equations; analytical redundancy; combined cycle power plant; differential equations; fault diagnosis; gas turbine; nonlinear complex dynamical model; sensors faults; structural analysis; Fault detection; Fault diagnosis; Heat recovery; Large-scale systems; Monitoring; Nonlinear equations; Power generation; Power industry; Redundancy; Turbines;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
American Control Conference, 2006
Conference_Location :
Minneapolis, MN
Print_ISBN :
1-4244-0209-3
Electronic_ISBN :
1-4244-0209-3
Type :
conf
DOI :
10.1109/ACC.2006.1657418
Filename :
1657418
Link To Document :
بازگشت