DocumentCode :
229763
Title :
Examination of cross current suppression method using control of parallel operation system constructed by two electric power converters
Author :
Nakai, Mitsuki ; Inaba, Hiromi ; Kishine, Keiji ; Ishikura, Keisuke ; Ito, Takao
Author_Institution :
Ishida Co., Ltd., Ishida, Japan
fYear :
2014
fDate :
22-25 Oct. 2014
Firstpage :
892
Lastpage :
897
Abstract :
A large-capacity power conversion system for a permanent magnet (PM) motor drive consisting of two or more converters has a lot of flexibility. However, it is important to suppress cross current between the two converters. This paper investigates the cross current suppression performance of each control method and provides useful hints about the current control loop gain setting and reactance of the combination reactor.
Keywords :
electric current control; motor drives; permanent magnet motors; power conversion; power convertors; PM; combination reactor reactance; cross current suppression method; current control loop gain setting; electric power converters; large-capacity power conversion system; parallel operation system; permanent magnet motor drive; Control systems; Current control; Frequency control; Inductors; Inverters; Pulse width modulation; Voltage control;