DocumentCode
2297671
Title
A seam-line removal method on mosaicing of CBCT images
Author
Xie Yichen ; Chen Jian ; Yan Bin ; Zeng Lei ; Tong Li ; Zeng Yin
Author_Institution
Nat. Digital Switching Syst. Eng. &Technol. R&D Center, Zhengzhou, China
fYear
2012
fDate
29-31 Dec. 2012
Firstpage
45
Lastpage
48
Abstract
Seam-line removal is very important in image mosaicing. Using traditional mosaicing methods to process the three-dimensional (3D) images by cone beam computed tomography (CBCT) usually produces obvious seams because of its high resolution and isotropic features. In this paper, we present a seam line removal method on mosaicing of CBCT images is presented. This method first takes makes a linear mapping to CT values to reduce overall differences of mosaic images, and then extends the feathering algorithm to 3D images. The experimental results indicate that the seams are effectively removed, which greatly improves the visual quality of the 3D image mosaicing.
Keywords
computerised tomography; electronic engineering computing; image reconstruction; image registration; image segmentation; printed circuits; 3D image mosaicing; CBCT image mosaicing; CT values; cone beam computed tomography; linear mapping; overall difference reduction; seam-line removal method; visual quality improvement; CBCT; feathering; mosaic; seam-line removal;
fLanguage
English
Publisher
ieee
Conference_Titel
Computer Science and Network Technology (ICCSNT), 2012 2nd International Conference on
Conference_Location
Changchun
Print_ISBN
978-1-4673-2963-7
Type
conf
DOI
10.1109/ICCSNT.2012.6525887
Filename
6525887
Link To Document