Title :
5-phase flux switching machine insulation failure detection using vibration monitoring
Author :
Ojeda, Javier ; Boisson, Julien ; Gabsi, Mohamed
Author_Institution :
SATIE, ENS Cachan, Cachan, France
Abstract :
This paper deals with the insulation fault diagnosis of a 5-phase Flux Switching Permanent magnet Motor (FSPM) using vibration measurements. Both cases of insulation faults are detailed (short-circuit and open-circuit faults) and the fault detection using the FSPM vibration are explained. The method is validated by experimental tests in a 5-phase FSPM.
Keywords :
fault diagnosis; permanent magnet motors; vibration measurement; 5-phase flux switching permanent magnet; FSPM vibration; insulation failure detection; open-circuit faults; short-circuit faults; vibration measurements; vibration monitoring; Circuit faults; Fault detection; Frequency measurement; Insulation; Stators; Vibration measurement; Vibrations;
Conference_Titel :
Electrical Machines and Systems (ICEMS), 2014 17th International Conference on
Conference_Location :
Hangzhou
DOI :
10.1109/ICEMS.2014.7013622