Experimental verification of dead-time compensation scheme for pulse width modulation scheme on six-switch two three-phase output inverter
Author :
Ikegami, Sho ; Hoshi, Nobukazu ; Haruna, Junnosuke
Author_Institution :
Dept. of Electr. Eng., Tokyo Univ. of Sci., Noda, Japan
fYear :
2014
fDate :
22-25 Oct. 2014
Firstpage :
1420
Lastpage :
1424
Abstract :
Six-switch two three-phase output inverter can be controlled by pulse width modulation (PWM) scheme. Each switching device used in voltage source inverter requires dead-time. The output waveform of the inverter is distorted when the dead-time is inserted. Therefore, the output current THD (total harmonics distortion) increases. Applying a dead-time compensation scheme, the distortion caused by the dead-time can be reduced. This paper shows the effectiveness of a dead-time compensation scheme which is applied to a PWM scheme for six-switch two three-phase output inverter by experiment.
Keywords :
PWM invertors; harmonic distortion; dead-time compensation scheme; output current THD; output waveform; pulse width modulation scheme; six-switch two three-phase output inverter; switching device; total harmonics distortion; voltage source inverter; Capacitors; Inverters; Load modeling; Permanent magnet motors; Pulse width modulation; Switches; Voltage control;