Abstract :
The limitations imposed by manufacturer´s power supply as well as load and cooling equipment make difficult to qualify the efficiency of high speed PMs machines. In addition, indirect methods outlined in IEEE, IEC and NEMA standards exclude considerations of permanent magnet synchronous machines. Besides some classical tests, we propose an indirect testing to evaluate the losses and then the efficiency of the high speed permanent magnet motor fed by a VFD. The testing needs only a VFD, the test machine and a LC filter.
Keywords :
machine testing; permanent magnet motors; synchronous motors; IEC standard; IEEE standard; LC filter; NEMA standard; cooling equipment; high speed PM machines; high speed synchronous permanent magnets motors; indirect testing; load equipment; loss determination; permanent magnet synchronous machines; test machine; Core loss; Hysteresis motors; Iron; Loss measurement; Rotors; Testing; Wires;