DocumentCode
2299911
Title
Factors affecting reliability of gold and copper in ball bonding
Author
Breach, C.D. ; Holliday, R.
Author_Institution
ProMat Consultants, Singapore, Singapore
fYear
2010
fDate
16-19 Aug. 2010
Firstpage
446
Lastpage
451
Abstract
Copper and gold ball bonds were bonded on 1.2 μm thick Al-0.5%Cu-1%Si. One set of devices was aged at 175°C up to 1000 hours. A second set of devices was pre-conditioned for 168 hours at 85°C and 85% relative humidity followed by ageing at 175°C up to 1000 hours. No cratering was found with either wire in as-bonded devices but devices bonded with copper developed cratering after ageing. Neck and stitch pull strengths of copper decreased with ageing and moisture pre-conditioning slightly accelerated loss of strength. Shear strength of copper wires increased during ageing above the levels observed with gold.
Keywords
ageing; bonding processes; copper; electronics packaging; gold; reliability; shear strength; wires; ageing; ball bonding; copper wires; shear strength; Aging; Bonding; Copper; Force; Gold; Intermetallic; Wire;
fLanguage
English
Publisher
ieee
Conference_Titel
Electronic Packaging Technology & High Density Packaging (ICEPT-HDP), 2010 11th International Conference on
Conference_Location
Xi´an
Print_ISBN
978-1-4244-8140-8
Type
conf
DOI
10.1109/ICEPT.2010.5583890
Filename
5583890
Link To Document