DocumentCode
2301522
Title
Testing of low-current contacts quality and reliability by using third harmonic distortion
Author
Hajek, K. ; Sikula, J.
Author_Institution
Dept. of Electron., Mil. Acad., Fac. of Air Force & Air Defense, Brno, Czech Republic
fYear
2003
fDate
10-10 Sept. 2003
Firstpage
211
Lastpage
213
Abstract
This paper shows a new possibility for quality and reliability testing of low-current contacts by their non-linearity measurement. A common THD tester cannot be used for low impedance elements. Therefore, a special variant of the THD tester was developed. It was used for testing a set of relay contacts. The results of the tests proved the applicability of the proposed method.
Keywords
distortion measurement; electrical contacts; harmonic distortion; relays; reliability; THD measurement; THD tester; THD-meter; contact quality; contact reliability; low impedance elements; low-current contact testing; nonlinearity measurement; relay contacts testing; third harmonic distortion; Band pass filters; Cutoff frequency; Distortion measurement; Harmonic distortion; Impedance measurement; Power harmonic filters; Relays; Resistors; Testing; Voltage;