• DocumentCode
    2301522
  • Title

    Testing of low-current contacts quality and reliability by using third harmonic distortion

  • Author

    Hajek, K. ; Sikula, J.

  • Author_Institution
    Dept. of Electron., Mil. Acad., Fac. of Air Force & Air Defense, Brno, Czech Republic
  • fYear
    2003
  • fDate
    10-10 Sept. 2003
  • Firstpage
    211
  • Lastpage
    213
  • Abstract
    This paper shows a new possibility for quality and reliability testing of low-current contacts by their non-linearity measurement. A common THD tester cannot be used for low impedance elements. Therefore, a special variant of the THD tester was developed. It was used for testing a set of relay contacts. The results of the tests proved the applicability of the proposed method.
  • Keywords
    distortion measurement; electrical contacts; harmonic distortion; relays; reliability; THD measurement; THD tester; THD-meter; contact quality; contact reliability; low impedance elements; low-current contact testing; nonlinearity measurement; relay contacts testing; third harmonic distortion; Band pass filters; Cutoff frequency; Distortion measurement; Harmonic distortion; Impedance measurement; Power harmonic filters; Relays; Resistors; Testing; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Contacts, 2003. Proceedings of the Forty-Ninth IEEE Holm Conference on
  • Conference_Location
    Washington, DC, USA
  • Print_ISBN
    0-7803-7862-8
  • Type

    conf

  • DOI
    10.1109/HOLM.2003.1246499
  • Filename
    1246499