• DocumentCode
    2304090
  • Title

    Low-Pressure Partial-Discharge Measurements: Monitoring the Insulation Integrity of Aircraft Power Wiring Systems

  • Author

    Schweickart, D.L. ; Grosjean, D.F. ; Kasten, D.G. ; Sebo, S.A. ; Liu, X.

  • Author_Institution
    Air Force Res. Lab., Wright-Patterson Air Force Base, OH
  • fYear
    2008
  • fDate
    27-31 May 2008
  • Firstpage
    568
  • Lastpage
    571
  • Abstract
    Partial-discharge (PD) characteristics in three gases (air, argon and helium) at pressures between 101 kPa (760 Torr) and about 0.27 kPa (2 Torr) under 60-Hz ac energization were studied. Measurements for two representative electrode configurations showed that the electrical characteristics of PD (specifically, electric pulse waveforms) at low pressures differ significantly from those at sea-level pressures. Difficulties in obtaining accurate measurements when adhering to guidelines defined by the IEC 60270 standard are described. Suggested modifications of the standard procedures are presented for measurement and calibration for low-pressure PD.
  • Keywords
    IEC standards; aircraft; cable insulation; partial discharge measurement; IEC 60270 standard; aircraft power wiring systems; insulation integrity monitoring; low-pressure partial-discharge measurements:; Aircraft; Argon; Gases; IEC standards; Insulation; Measurement standards; Monitoring; Power measurement; Pulse measurements; Wiring;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    IEEE International Power Modulators and High Voltage Conference, Proceedings of the 2008
  • Conference_Location
    Las Vegas, NE
  • Print_ISBN
    978-1-4244-1534-2
  • Electronic_ISBN
    978-1-4244-1535-9
  • Type

    conf

  • DOI
    10.1109/IPMC.2008.4743722
  • Filename
    4743722