Title :
Calibration procedure for short focal length off-the-shelf CCD cameras
Author :
Heikkilä, Janne ; Silvén, Olli
Author_Institution :
Dept. of Electr. Eng., Oulu Univ., Finland
Abstract :
A camera calibration procedure intended for a 3D measurement application is presented, paying attention to the various error sources. The error may be measurement noise that is random by nature, but it may also be systematic originating from the calibration target used, geometrical distortions and illumination. In order to obtain good calibration results, the systematic error sources should be eliminated or their effects compensated for. Then, the camera parameters can be determined by fitting the corrected measurements to the camera model which in our case is a combination of a pinhole camera and lens distortion models. We also notice that a more complete camera model is needed to explain all the error components
Keywords :
CCD image sensors; brightness; calibration; lighting; noise; optical noise; stereo image processing; video cameras; 3D measurement; CCD cameras; camera calibration; camera model; geometrical distortions; illumination; lens distortion models; measurement noise; pinhole camera; Calibration; Cameras; Charge coupled devices; Charge-coupled image sensors; Costs; Distortion measurement; Electric variables measurement; Lenses; Machine vision; Optical distortion;
Conference_Titel :
Pattern Recognition, 1996., Proceedings of the 13th International Conference on
Conference_Location :
Vienna
Print_ISBN :
0-8186-7282-X
DOI :
10.1109/ICPR.1996.546012