DocumentCode
2306865
Title
Ultra-Wideband Data Acquisition Circuit Based on Nonperiodic Equivalent Sampling
Author
Fang, Bingyi ; Li, Xi
Author_Institution
Dept. of Electron. Eng., Beijing Inst. of Technol.
fYear
2006
fDate
22-24 Sept. 2006
Firstpage
1
Lastpage
4
Abstract
A new equivalent sampling circuit for nonperiodic UWB signal is presented in this paper. In order to sampling the UWB narrow pulse effectively, the sampling speed must be very high according to the Nyquist law, the equivalent sampling method is a valid solution in a simple way. However, the condition for the traditional equivalent sampling is that the signals to be measured are periodic or duplicate, so it´s necessary to improve the equivalent sampling method to adapt to the nonperiodic UWB pulses train after PPM, which changed the intervals of pulses according to PN code. Experimental results of this implementing circuit are provided to demonstrate the effectiveness and feasibility of the proposed method
Keywords
data acquisition; pseudonoise codes; signal processing equipment; ultra wideband communication; Nyquist law; PN code; nonperiodic equivalent sampling; ultra-wideband data acquisition circuit; Bandwidth; Circuit testing; Data acquisition; Data engineering; FCC; Pulse measurements; Pulse modulation; Radar applications; Sampling methods; Ultra wideband technology;