DocumentCode
2311127
Title
A CMOS VLSI implementation of Mean Life Time (MLT) Detector for Bio-luminescence Sensor
Author
Guhilot, Hansraj ; Kamat, R.K.
Author_Institution
Dept. of E & C, K.L.E. Soc.´´s Coll. of Eng. & Technol., Belgaum, India
fYear
2010
fDate
12-13 March 2010
Firstpage
164
Lastpage
167
Abstract
This paper describes a novel analog front end sensor signal processing block for applications like Bio-fluorescence, tomography, DNA fingerprints. Along with the principle a detailed design is presented in 120 nm technology. Analog simulations are done using LT Spice version IV and Layout is done using Microwind 3.1 this sensor design differs from all previous designs used in Active pixel sensors. This can be taken as improved correlated double integration method of single event detector.
Keywords
CMOS integrated circuits; SPICE; VLSI; bioluminescence; biomedical electronics; CMOS VLSI; DNA fingerprints; LT Spice version IV and Layout; Microwind 3.1; analog front end sensor signal processing; biofluorescence; bioluminescence sensor; mean life time detector; size 120 nm; tomography; Biomedical signal processing; Biosensors; CMOS technology; DNA; Detectors; Event detection; Fingerprint recognition; Sensor phenomena and characterization; Tomography; Very large scale integration; Bio-luminescence; Mean life time detector; active pixel; correlated double integrator; photosynthesis;
fLanguage
English
Publisher
ieee
Conference_Titel
Recent Trends in Information, Telecommunication and Computing (ITC), 2010 International Conference on
Conference_Location
Kochi, Kerala
Print_ISBN
978-1-4244-5956-8
Type
conf
DOI
10.1109/ITC.2010.61
Filename
5460592