DocumentCode :
231331
Title :
Diagnosis method for open-circuit fault of cascade-STATCOM based on analytical model
Author :
Guo Yongdong
Author_Institution :
Henan Polytech. Univ., Jiaozuo, China
fYear :
2014
fDate :
28-30 July 2014
Firstpage :
3136
Lastpage :
3140
Abstract :
The reliability of the power switch will directly influence the safety and reliability of STATCOM (Static Synchronous Compensator). However, it is difficult to detect the open-circuit fault because the output current and voltage are changed slightly in cascade-STATCOM. In this paper, we apply double Fourier transform of the switching function to analyze the distinction between normal fault and open-circuit fault, and propose that the open-circuit can be diagnosed by detecting the DC capacitor voltage. Moreover, this method resorts no additional sensors. The discriminant is also given in the paper. Simulation examples are presented in the end to illustrate the correctness of the theoretical result.
Keywords :
Fourier transforms; electrical safety; fault diagnosis; power capacitors; power system reliability; static VAr compensators; switchgear; DC capacitor voltage detection; cascade-STATCOM; double Fourier transform; open-circuit fault detection; open-circuit fault diagnosis method; power switch reliability; safety; sensor; static synchronous compensator; switching function; Automatic voltage control; Capacitors; Circuit faults; Fluctuations; Inverters; Switches; analytical model; cascade-STATCOM; double Fourier transform; open-circuit fault of power switch;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Control Conference (CCC), 2014 33rd Chinese
Conference_Location :
Nanjing
Type :
conf
DOI :
10.1109/ChiCC.2014.6895453
Filename :
6895453
Link To Document :
بازگشت