DocumentCode :
2315618
Title :
An algorithm, based on autocorrelation function evaluation, for the separation of partial discharge signals
Author :
Contin, Alfredo ; Pastore, Stefano
Author_Institution :
D.E.E.I., Trieste Univ., Italy
fYear :
2004
fDate :
19-22 Sept. 2004
Firstpage :
127
Lastpage :
130
Abstract :
An innovative classification method for the automatic separation of partial discharge signals, based on the auto and cross correlation function evaluation, is presented in this paper. Two different parameters, derived from the analysis of these two functions, are used to evaluate the similarity of signal shapes. Reasonable threshold levels have been established as a good compromise between strong and weak discrimination between pulses. Examples of application of the proposed algorithm to data from laboratory tests are reported and discussed to show the validity of the method.
Keywords :
fault diagnosis; insulation testing; partial discharge measurement; power apparatus; HV apparatus; autocorrelation function; cross correlation function; partial discharge signal; signal shape; threshold level; Autocorrelation; Clustering algorithms; Insulation; Laboratories; Noise shaping; Partial discharges; Performance evaluation; Shape; Signal analysis; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electrical Insulation, 2004. Conference Record of the 2004 IEEE International Symposium on
ISSN :
1089-084X
Print_ISBN :
0-7803-8447-4
Type :
conf
DOI :
10.1109/ELINSL.2004.1380484