• DocumentCode
    2317280
  • Title

    Beam measurements at the GSI high current injector

  • Author

    Barth, William ; Dahl, L. ; Glatz, J. ; Forck, P. ; Klabunde, J.

  • Author_Institution
    GSI, Darmstadt, Germany
  • Volume
    5
  • fYear
    2001
  • fDate
    2001
  • Firstpage
    3281
  • Abstract
    The GSI UNILAC was upgraded as a high current injector for the heavy ion synchrotron SIS in 1999. During that time a versatile beam diagnostics test bench served for commissioning after each acceleration and transport section. After completion of the new linac, beam measurements have been carried out along the UNILAC at selected positions. The effects of high space charge forces could be analyzed. The beam emittance along the linac, the influence of the gas and foil strippers on beam quality, and emittance measurements at various beam energies (0.002 to 11.4 MeV/u) will be reported. Multiparticle simulations were performed and compared with beam measurements
  • Keywords
    ion accelerators; linear accelerators; particle beam diagnostics; particle beam dynamics; particle beam injection; space charge; UNILAC; beam diagnostics; beam emittance; beam measurement; beam quality; foil stripper; gas stripper; high current injector; multiparticle simulations; space charge forces; Current measurement; Energy measurement; Life estimation; Linear particle accelerator; Particle beams; Performance evaluation; Position measurement; Space charge; Synchrotrons; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 2001. PAC 2001. Proceedings of the 2001
  • Conference_Location
    Chicago, IL
  • Print_ISBN
    0-7803-7191-7
  • Type

    conf

  • DOI
    10.1109/PAC.2001.988084
  • Filename
    988084