Evaluation of 23 kV insulator profiles with different pollution levels
Author :
Herndndez-Corona, R. ; Ramirez- Vazquez, I. ; Montoya-Tena, Gerardo
Author_Institution :
Inst. de Investigaciones Electricas, Cuernavaca, Mexico
Abstract :
Insulators used for 23 kV distribution lines working under high pollution conditions were removed from field. These insulators were evaluated in a fog chamber. The results showed that the insulator profile has a strong effect on the performance of the insulator under very heavy pollution and humidity conditions. Insulators having a simple profile electrically failed under light pollution conditions. While, insulators having a complex profile did not fail under very heavy pollution conditions. The results obtained for each insulator evaluated are presented in This work.
Keywords :
fog; insulator contamination; insulator testing; power distribution lines; 23 kV; distribution lines; fog chamber; humidity conditions; insulator profiles; pollution conditions; Dielectrics and electrical insulation; Flashover; Humidity; Laboratories; Measurement standards; Pollution measurement; Sea level; Surface contamination; Urban pollution; Voltage;