• DocumentCode
    2317559
  • Title

    Partial discharge characteristics of the ultra-high voltage cable insulators according to the measuring temperature

  • Author

    Lee, Kang-Won ; Park, Young-Ha ; Park, Hee-Doo ; Kim, Gwi-Yeol ; Yeon, Kyu-Hoo ; Lee, Chung-Ho ; Hong, Jin-woong

  • Author_Institution
    Kwangwoon Univ., Seoul
  • fYear
    2008
  • fDate
    21-24 April 2008
  • Firstpage
    105
  • Lastpage
    108
  • Abstract
    In this paper, it is investigated the effect of the cross linked polyethylene (XLPE) insulators was examined according to the temperature into XLPE which was used as the insulation of the electric power cable for the ultra-high voltage. In order to investigate the effect of changing tree phenomenon according to the temperature on the electrical conduction mechanism, a partial discharge experiment was conducted through the variation of temperature from 25[degC] to 80[degC], and voltage applied to the electrodes from 1[kV] to 40[kV]. The activity of partial discharge according to the temperature was examined using k-means distribution. As a result of experiments, we found that the specimen with 80[degC] has the lowest inception and breakdown voltage, center of clusters move 0, 180 degree at each positive and negative region in the k-means. We obtained that distribution of clusters concentrated on at inception condition, but the distribution spreads out widely at breakdown.
  • Keywords
    XLPE insulation; insulators; partial discharges; power cable insulation; temperature measurement; XLPE; cross linked polyethylene insulators; electric power cable; electrical conduction mechanism; partial discharge; temperature measurement; ultra-high voltage; ultrahigh voltage cable insulators; Cable insulation; Dielectrics and electrical insulation; Partial discharge measurement; Partial discharges; Polyethylene; Power cable insulation; Power cables; Temperature measurement; Trees - insulation; Voltage; Cable insulator; Cluster; K-means; Partial discharge; Temperature; XLPE;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-1621-9
  • Electronic_ISBN
    978-1-4244-1622-6
  • Type

    conf

  • DOI
    10.1109/CMD.2008.4580241
  • Filename
    4580241