• DocumentCode
    2317652
  • Title

    The use of conductivity factors for estimating the degradation state of insulation systems of medium-power electrical machines

  • Author

    Notingher, P.V. ; Dumitran, L.M. ; Busoi, S. ; Balescu, E. ; Tanasescu, G.

  • Author_Institution
    Politeh. Univ. of Bucharest, Bucharest
  • fYear
    2008
  • fDate
    21-24 April 2008
  • Firstpage
    126
  • Lastpage
    129
  • Abstract
    The use of absorption/resorption currents to characterize the ageing state of electrical equipmentspsila insulation systems is well known. The maximal values and the slopes of these currents give important information regarding the paper-oil insulations for power transformers and energy cables, but these are also used for insulation systems of medium and/or high power machines. In general, the values of the conductivity factors are rarely used.
  • Keywords
    ageing; electrical conductivity; insulation testing; machine insulation; ageing state; conductivity factor; electrical equipment insulation systems; insulation degradation; mediumpower electrical machines; Absorption; Aging; Cable insulation; Cables; Conductivity; Degradation; Dielectrics and electrical insulation; Power transformer insulation; Power transformers; State estimation; Absorption/resorption currents; Insulation systems; Rotating machines; Thermal ageing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Condition Monitoring and Diagnosis, 2008. CMD 2008. International Conference on
  • Conference_Location
    Beijing
  • Print_ISBN
    978-1-4244-1621-9
  • Electronic_ISBN
    978-1-4244-1622-6
  • Type

    conf

  • DOI
    10.1109/CMD.2008.4580246
  • Filename
    4580246