Title :
Automatic detection of heart disease from twelve channel electrocardiogram waveforms
Author :
Zimmerman, TG ; Syeda-Mahmood, T.
Author_Institution :
IBM Almaden Res. Center, San Jose, CA
fDate :
Sept. 30 2007-Oct. 3 2007
Abstract :
A statistical means to automatically detect heart disease from twelve channel ECG waveforms is reported. Patient ECG records from the PTB Diagnostic ECG Database are assigned to one or more of 18 heart disease groups. A single heart beat cycle near the beginning of the record is used to measure eight temporal intervals (e.g. QT, ST, PR, QS) for each of the twelve channels, resulting in 96 parameters for each patient record. The average and standard deviation of the 96 parameters for 63 non-disease patients are used as a control reference. The number of parameters that exceed two times the standard deviation of the control reference is used as a disease indicator. Using ten or more out-of-bound parameters as the disease criteria, 72% of disease patient records are correctly identified while 8% of control patient records are falsely identified as having a heart disease.
Keywords :
diseases; electrocardiography; patient diagnosis; ECG waveforms; PTB Diagnostic ECG Database; automatic heart disease detection; twelve channel electrocardiogram waveforms; Atrial fibrillation; Cardiac disease; Cardiology; Cardiovascular diseases; Coronary arteriosclerosis; Databases; Electrocardiography; Heart beat; Hypertension; Medical diagnosis;
Conference_Titel :
Computers in Cardiology, 2007
Conference_Location :
Durham, NC
Print_ISBN :
978-1-4244-2533-4
Electronic_ISBN :
0276-6547
DOI :
10.1109/CIC.2007.4745609