Abstract
A physical approach is employed to estimate the rotor flux for a position sensorless induction machine drive system. This approach is based on the fundamental operating characteristics of the induction machine. The estimator structure calculates the rotor flux accurately at low speeds, and is largely insensitive to parameter variations. System structure, theoretical analysis, simulation, and laboratory results are presented
Keywords
digital simulation; electric drives; electric machine analysis computing; induction motors; machine control; machine theory; magnetic flux; parameter estimation; rotors; simulation; estimator structure; fundamental operating characteristics; induction machine drive system; parameter insensitivity; position sensorless field orientation control; robust control; rotor flux estimation; simulation; theoretical analysis; Analytical models; Control systems; Electrical equipment industry; Equations; Frequency estimation; Induction machines; Laboratories; Physics; Position control; Robust control; Robustness; Sensorless control;