Effect of negative sequence torque on induction motor plant during transient fault conditions
Author :
El-Mohr, Ibrahim M.
Author_Institution :
AAST, Alexandria, Egypt
Volume :
1
fYear :
1998
fDate :
18-21 Aug 1998
Firstpage :
591
Abstract :
An interconnected power system containing synchronous and induction machines has been simulated. The total fault current and the behavior of each machine have been calculated under single line-to-ground fault conditions for a fault time of 500 ms. The negative sequence torque has been calculated for faulted and unfaulted machines. The results show the importance of the negative sequence torque in decreasing the rotor swing amplitudes of synchronous machines during the fault period, while it has a deleterious effect on induction motor speeds which tend to run-down such that they may be unable to recover during the post-fault period
Keywords :
induction motors; machine theory; power system faults; power system interconnection; power system transients; rotors; torque; 500 ms; fault time; induction motor plant; interconnected power system; negative sequence torque; post-fault period recovery; rotor swing amplitudes; single line-to-ground fault; speed run-down; synchronous machines; transient fault conditions; Circuit faults; Differential equations; Fault currents; Induction machines; Induction motors; Power system transients; Rotors; Synchronous machines; Synchronous motors; Torque;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Power System Technology, 1998. Proceedings. POWERCON '98. 1998 International Conference on
Conference_Location :
Beijing
Print_ISBN :
0-7803-4754-4
Type :
conf
DOI :
10.1109/ICPST.1998.729033
Filename :
729033
Link To Document :
بازگشت