  • Abstract
    A measurement system combining vector corrected waveform measurements with active harmonic load-pull extends, for the first time, real-time experimental waveform engineering up to the 30 W power level. This novel harmonic load-pull approach is demonstrated on a 4 W LDMOS device. A 20% increase in maximum output power to 4.7 W without degrading gain and efficiency was realized.
  • Keywords
    MOSFET circuits; UHF circuits; UHF power amplifiers; circuit tuning; time-domain analysis; 30 W; 4 to 4.7 W; LDMOS device; active harmonic load-pull; efficiency; gain; high efficiency base station amplifier; high power time domain measurement system; maximum output power; measurement system; vector corrected waveform measurements; waveform engineering; Base stations; High power amplifiers; Packaging; Power amplifiers; Power generation; Power measurement; Power system harmonics; System testing; Time measurement; Voltage;