• DocumentCode
    2329970
  • Title

    Carbon Contamination Free Wafer Cleaning

  • Author

    Yonekawa, N. ; Yasui, S. ; Ojima, S. ; Ohmi, T.

  • Author_Institution
    Tohoku University
  • fYear
    1994
  • fDate
    21-22 June 1994
  • Firstpage
    219
  • Lastpage
    220
  • Abstract
    It is difficult not only to detect a small volume of hydrocarbons on Si wafer surface but also to remove the organic impurities by conventional dipping cleaning. Therefore, new analysis method and new cleaning method are required in the semiconductor manufacturing. We have developed the advanced Dynamic-Spin Cleaning System with the ozonized ultrapure water. The experimental results demonstrate that this system is more effective than the conventional dipping cleaning. And then hydrocarbons were confirmed by FT-IR-ATR method. Generally, this method can not detect the very small volume of hydrocarbons. However, this problem is solved by using an ATR-prism made from other materials, like as germanium. Using other materials as ATR-prism can correct exact background spectrum. Therefore, a very small amount of organic impurities can be detected.
  • Keywords
    Cleaning; Gas detectors; Germanium; Hydrocarbons; Pollution measurement; Semiconductor device manufacture; Semiconductor impurities; Surface contamination; Surface treatment; Water pollution;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Semiconductor Manufacturing, 1994. Extended Abstracts of ISSM '94. 1994 International Symposium on
  • Conference_Location
    Tokyo, Japan
  • Type

    conf

  • DOI
    10.1109/ISSM.1994.729462
  • Filename
    729462