• DocumentCode
    2332324
  • Title

    Operational results for the raster scanning power supply system constructed at the Bevalac Biomedical Facility

  • Author

    Stover, G. ; Halliwell, J. ; Nyman, M. ; Dwinell, R.

  • Author_Institution
    Lawrence Berkeley Lab., California Univ., CA, USA
  • fYear
    1989
  • fDate
    20-23 Mar 1989
  • Firstpage
    1890
  • Abstract
    A raster scanning power supply for controlling an 8.0-T-m relativistic heavy-ion beam at the Bevalac Biomedical Facility has been completed recently and is undergoing electrical testing before online operation in 1989. The scanner system will provide tightly controlled beam uniformity and off-axis treatment profiles with large aspect ratios and unusual dimensions. Original specifications, agreement with measured results, and special device performance (i.e. gate turn-on thyristor switches, field-effect transistor actuator assembly, etc.) are discussed. Firing circuit tests have been completed, and full four quadrant operation with the beam through the magnet was demonstrated on March 15, 1989
  • Keywords
    beam handling equipment; beam handling techniques; ion accelerators; nuclear electronics; power supplies to apparatus; synchrotrons; Bevalac Biomedical Facility; beam uniformity; field-effect transistor actuator assembly; four quadrant operation; gate turn-on thyristor switches; off-axis treatment profiles; online operation; raster scanning power supply; relativistic heavy-ion beam; scanner system; Actuators; Assembly; Biomedical measurements; Circuit testing; Control systems; FETs; Magnetic field measurement; Power supplies; Switches; Thyristors;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1989. Accelerator Science and Technology., Proceedings of the 1989 IEEE
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/PAC.1989.72959
  • Filename
    72959