• DocumentCode
    2333246
  • Title

    Photoelectric detector used for object sorting

  • Author

    Kagan, S. ; Gabay, E. ; Bergman, J.

  • Author_Institution
    Center for Technol. Educ., Holon, Israel
  • fYear
    1995
  • fDate
    7-8 March 1995
  • Abstract
    In radiometric separators the decision about the sample quality is based on the analysis of the output signal. In this paper we present a general description and applications of the geometrical and physical factors concept in the analysis of photodetector output signals as function of technical parameters and physical characteristics of the source, the detector and the sample. The method of a group "average" spectrum is proposed for the purpose of effective accounting of various spectral properties of the samples.
  • Keywords
    object recognition; photodetectors; sorting; spectral analysis; geometrical factor; group average spectrum; object sorting; photoelectric detector; radiometric separator; sample quality; signal analysis; Automatic control; Educational technology; Object detection; Particle separators; Radiation detectors; Radiometry; Scattering; Signal analysis; Sorting; Testing;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Electronics Engineers in Israel, 1995., Eighteenth Convention of
  • Conference_Location
    Tel Aviv, Israel
  • Print_ISBN
    0-7803-2498-6
  • Type

    conf

  • DOI
    10.1109/EEIS.1995.513834
  • Filename
    513834