Abstract
Sequencer-type application programs are used to turn on several accelerator systems at Fermilab. One of the first systems to use such a program was the Tevatron main power supply system. The function of TARCAS (Tevatron Automated Ramp Check-out and Start-up) is discussed. A brief summary of the operation experience with such sequencer programs is also presented
Keywords
proton accelerators; synchrotrons; Fermilab; TARCAS; Tevatron Automated Ramp Check-out and Start-up; Tevatron main power supply system; accelerator systems; sequencer programs; Cryogenics; Hardware; Laboratories; Linear accelerators; Monitoring; Power supplies; Power system protection; Switches; Testing; Turning;