• DocumentCode
    2334735
  • Title

    Reliability comparison of boost PFC converter in DCM and CCM operating modes

  • Author

    Abdi, B. ; Ranjbar, A.H. ; Milimonfared, J. ; Gharehpetian, G.B.

  • Author_Institution
    Dept. of Electr. Eng., Amirkabir Univ. of Technol., Tehran
  • fYear
    2008
  • fDate
    11-13 June 2008
  • Firstpage
    939
  • Lastpage
    943
  • Abstract
    Reliability plays an important role in power electronic systems by which the number of system failures, repair costs, guarantee and etc are estimated. In this paper first, a boost power factor correction (PFC) converter is simulated in discontinues conduction mode (DCM) and continuous conduction mode (CCM) under different output power ratings. For these simulations, all of the inherent parameters of MOSFET and diodes are applied according to the actual types. Then, reliability calculation is done based on MIL-HDBK-217 standard. Results have shown that the boost PFC converter would have better performance from reliability point of view in CCM operating mode.
  • Keywords
    fault diagnosis; maintenance engineering; power MOSFET; power convertors; power factor correction; reliability; MIL-HDBK-217 standard; MOSFET; PFC converter; boost PFC converter; boost power factor correction; continuous conduction mode; discontinues conduction mode; operating modes; power electronic systems; repair costs; system failures; Circuits; Costs; Power electronics; Power factor correction; Power generation; Power supplies; Power system reliability; Stress; Switching converters; Voltage; Boost; Converter; PFC; Reliability;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics, Electrical Drives, Automation and Motion, 2008. SPEEDAM 2008. International Symposium on
  • Conference_Location
    Ischia
  • Print_ISBN
    978-1-4244-1663-9
  • Electronic_ISBN
    978-1-4244-1664-6
  • Type

    conf

  • DOI
    10.1109/SPEEDHAM.2008.4581288
  • Filename
    4581288