• DocumentCode
    2336003
  • Title

    Design, fabrication, and calibration of curved integral coils for measuring transfer function, uniformity and effective length of LBL ALS booster dipole magnets

  • Author

    Green, M.I. ; Nelson, D. ; Marks, S. ; Gee, B. ; Wong, W. ; Meneghetti, J.

  • Author_Institution
    Lawrence Berkeley Lab., California Univ., CA, USA
  • fYear
    1989
  • fDate
    20-23 Mar 1989
  • Firstpage
    1972
  • Abstract
    A matched pair of curved integral coils has been designed, fabricated, and calibrated at Lawrence Berkeley Laboratory (LBL) for measuring Advanced Light Source (ALS) booster dipole magnets. Distinctive fabrication and calibration techniques are presented. The use of multifilar magnet wire in fabricating integral search coils is described. Magnetic measurements are discussed
  • Keywords
    calibration; coils; length measurement; magnetic field measurement; ALS booster dipole magnets; calibration; curved integral coils; design; effective length; fabrication; integral search coils; magnetic field measurement; multifilar magnet wire; transfer function; uniformity; Calibration; Coils; Extraterrestrial measurements; Fabrication; Laboratories; Magnetic field measurement; Magnets; Synchrotrons; Transfer functions; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1989. Accelerator Science and Technology., Proceedings of the 1989 IEEE
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/PAC.1989.72987
  • Filename
    72987