    Typical schemes of feeder automation for rural areas of China

  • Author

    Xu, Yinghui ; Xu, Xiaohui

  • Author_Institution
    Sch. of Autom., Guangdong Univ. of Technol., Guangzhou
  • fYear
    2008
  • fDate
    24-27 Nov. 2008
  • Firstpage
    680
  • Lastpage
    683
  • Abstract
    In China, some electric power companies of rural areas have installed many kinds of devices and systems supporting distribution automation systems (DAS). This paper generalized prerequisite for DAS, such as improving the network structure and reinforcing management. The practical application situations of centralized control mode are described. Three types of local control mode DAS are analyzed, including: fault indicator type, voltage-time type and voltage-current-time type. Protective setting coordination of different switches on feeders is analyzed. Some improvements have been made to reduce the outage shock on fault processing, such as simple master station and limitation of the range of protective setting of reclosers. In China, most distribution networks are configured as small current grounded systems; three methods to select the single-phase-to-ground fault feeder are analyzed, including: 1) fault selection devices in substation, 2) combination of substation devices with pole mounted field terminal units (FTUs) and 3) automatic tripping and judging the fault feeder. Considering the extreme climate of north and southern areas of China, the designs of batteries and terminals are generalized.
  • Keywords
    centralised control; earthing; power distribution control; power distribution faults; power distribution protection; power system management; substations; China; DAS; centralized control mode; distribution automation system; distribution network; electric power company; fault selection device; mounted field terminal unit; protective setting coordination; reinforcing management; single-phase-ground fault feeder system; small current grounded system; substation device; Automation; distribution automation systems (DAS); fault indicator type; feeder automation; field terminal unit (FTU); general packet radio service (GPRS); local control mode; single-phase-to-ground faults; small current grounded system; voltage-time type;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Sustainable Energy Technologies, 2008. ICSET 2008. IEEE International Conference on
  • Conference_Location
    Singapore
  • Print_ISBN
    978-1-4244-1887-9
  • Electronic_ISBN
    978-1-4244-1888-6
  • Type

    conf

  • DOI
    10.1109/ICSET.2008.4747093
  • Filename
    4747093