  • Abstract
    In normal dogs, SPECT Tc-99m Sestamibi (MIBI) Tl-201 myocardial perfusion images reconstructed with filtered backprojection (FBP) show a large decrease of counts in the septal wall (S) compared to the lateral wall (L). We evaluated the iterative method of Chang at 0 and 1 iterations (Chang0 and Chang1), and the Maximum Likelihood-Expectation Maximization with attenuation compensation (ML-EM-ATN) algorithm on data acquired from 5 normal dogs and from simulated projection data using a homogeneous count-density model of a normal canine myocardium in the attenuation field measured in one dog. Mean counts in the S and L regions were calculated from maximum-count circumferential profile arrays. Our results demonstrate that ML-EM-ATN and Chang1 result in improved uniformity, as measured by the S/L ratio
  • Keywords
    cardiology; image reconstruction; iterative methods; maximum likelihood estimation; medical image processing; single photon emission computed tomography; 201Tl; 99mTc; Maximum Likelihood-Expectation Maximization; SPECT Tc-99m Sestamibi; SPECT bull´s-eyes; Tc; Tl; Tl-201 myocardial perfusion images; attenuation compensation algorithms; filtered backprojection; heterogeneity; homogeneous count-density model; improved uniformity; iterative method; lateral wall; maximum-count circumferential profile arrays; normal canine myocardium; normal dogs; septal wall; simulated projection data; Animals; Attenuation; Biomedical imaging; Biomedical measurements; Computer simulation; Dogs; Image reconstruction; Iterative algorithms; Iterative methods; Myocardium;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Conference_Location
    Norfolk, VA
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474731
  • Filename
    474731