• DocumentCode
    2348797
  • Title

    Experience with Phase II insertion devices in the X-ray ring

  • Author

    Decker, G. ; Galayda, J. ; Krinsky, S. ; Solomon, L.

  • Author_Institution
    Brookhaven Nat. Lab., Upton, NY, USA
  • fYear
    1989
  • fDate
    20-23 Mar 1989
  • Firstpage
    470
  • Abstract
    The installation of Phase II insertion devices in the NSLS (National Synchrotron Light Source) X-ray ring was completed in February 1989, when the hybrid wiggler magnet (HBW) for beam line X21 and the superconducting wiggler (SCW) for beam line X17 were installed. Prior to this time, the soft X-ray undulator at X1, another hybrid wiggler at X25, and the ten-period miniundulator at X13 had been installed. Four of the insertion devices have generated light which has been brought out to the X-ray floor,. Characterization of these devices is continuing, with full commissioning anticipated in the future. Attention is given to thermal considerations, orbit control, and vertical tune shift
  • Keywords
    X-ray production; beam handling equipment; electromagnets; electron accelerators; storage rings; superconducting magnets; synchrotron radiation; NSLS; National Synchrotron Light Source; Phase II insertion devices; X-ray ring; hybrid wiggler magnet; orbit control; soft X-ray undulator; superconducting wiggler; thermal considerations; vertical tune shift; Cobalt; Electron beams; Energy resolution; Magnetic devices; Magnetic materials; Particle beams; Superconducting magnets; Synchrotrons; Undulators; X-ray imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Particle Accelerator Conference, 1989. Accelerator Science and Technology., Proceedings of the 1989 IEEE
  • Conference_Location
    Chicago, IL
  • Type

    conf

  • DOI
    10.1109/PAC.1989.73082
  • Filename