• DocumentCode
    2351195
  • Title

    A comparison of 3D scatter correction methods in a neuroPET tomograph

  • Author

    Spinks, TJ ; Grootoonk, S. ; Bailey, DL ; Schnorr, L.

  • Author_Institution
    Clinical Sci. Centre, Hammersmith Hospital, London, UK
  • Volume
    4
  • fYear
    1994
  • fDate
    30 Oct-5 Nov 1994
  • Firstpage
    1618
  • Abstract
    A comparison has been made between two procedures for scatter correction of 3D PET data acquired on a brain scanner (CTI/Siemens 953B). The methods are (i) dual energy window (DW), in which a weighted subtraction of data in a scatter window (200-380 keV) is made from the photopeak (380-850 keV) and (ii) convolution-subtraction (CS), in which a space-invariant kernel is derived from line source data. In multi-compartment phantoms, contrast ratios were restored to within about 6% of their true values with similar results for DW and CS. For both methods, good correction was observed in inactive water-filled compartments but residual counts were observed in air-filled cavities. Data from a patient injected with FDG was obtained by acquiring a 3D frame immediately after a standard 2D dynamic acquisition. Comparison of 2D and 3D images (scaled in kBq/ml using cross-calibration factors derived from phantoms) was made by plotting corresponding 8 mm square ROIs over the whole brain. The slopes/intercepts of these plots (ideally 1.0 and 0) were 0.97/-0.008 (DW), 0.95/-0.006 (CS) and 1.18/0.028 (uncorrected). Thus, overall similar results were obtained for the two methods although the noise in the corrected data was slightly higher for DW than for CS
  • Keywords
    brain; medical image processing; positron emission tomography; 200 to 850 keV; 2D dynamic acquisition; 3D frame; 3D scatter correction methods; 8 mm; brain scanner; contrast ratios; convolution-subtraction; line source data; medical diagnostic imaging; multicompartment phantoms; neuroPET tomograph; nuclear medicine; photopeak; residual counts; scatter window; space-invariant kernel; weighted data subtraction; Algorithm design and analysis; Attenuation; Brain; Cyclotrons; Hospitals; Image reconstruction; Imaging phantoms; Large Hadron Collider; Positron emission tomography; Scattering;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Nuclear Science Symposium and Medical Imaging Conference, 1994., 1994 IEEE Conference Record
  • Conference_Location
    Norfolk, VA
  • Print_ISBN
    0-7803-2544-3
  • Type

    conf

  • DOI
    10.1109/NSSMIC.1994.474753
  • Filename
    474753