Abstract :
The author describes an experimental investigation in which measurements of junction-to-case thermal resistance, θjc , of a 132-pin cavity-down ceramic (PGA) pin grid array package are compared to finite element (FEM) calculations. The initial goal of this work was to validate FEM predictions of θjc with measurements in accordance with the established SEMI and MIL standards. A serious problem was discovered in measuring accurate case temperatures, resulting in poor agreement between measured and predicted θjc. Detailed 3-D FEM simulations were used to analyze thermocouple measurement problems in the region between the case and cold plate. New methods were developed using fiber-optic thermometry and surface-junction thermocouples
Keywords :
fibre optic sensors; finite element analysis; measurement errors; packaging; spectral methods of temperature measurement; temperature measurement; thermal resistance; thermocouples; FEM; case temperature measurement errors; ceramic PGA; fiber-optic thermometry; junction-to-case thermal resistance; pin grid array package; surface-junction thermocouples; thermal simulation; thermocouple measurement problems; Analytical models; Ceramics; Cold plates; Computational modeling; Computer aided software engineering; Electrical resistance measurement; Electronics packaging; Heat sinks; Temperature measurement; Thermal resistance;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Semiconductor Thermal Measurement and Management Symposium, 1991. SEMI-THERM VII. Proceedings., Seventh Annual IEEE
Conference_Location :
Phoenix, AZ
Print_ISBN :
0-87942-664-0
Type :
conf
DOI :
10.1109/STHERM.1991.152910
Filename :
152910
Link To Document :
بازگشت