Long term clinical evaluation of Ha-coated titanium dental implant for single tooth
Author :
Pal, T.K. ; Pal, S.
Author_Institution :
Dept. of Periodontics, Dr. R. Ahmed Dental Coll. & Hospital, Calcutta, India
fYear :
1995
fDate :
15-18 Feb 1995
Firstpage :
25993
Lastpage :
26359
Abstract :
A single-stage long-term clinical trial was given for indigenously prepared hydroxyapatite coated titanium screw-type dental implant in six young adults using suitably designed and produced implant kit. Under local anaesthesia, bone was drilled at a very low speed (30 rpm) and implants were screwed in place. Clinical mobility was tested and radiographs were taken at a periodical interval up to 30 months. The implants were found to be clinically successful and radiographically acceptable
Keywords :
prosthetics; titanium; 30 month; Ha-coated titanium dental implant; Ti; bone drilling; clinically successful implants; hydroxyapatite coated titanium screw-type dental implant; implant kit; local anaesthesia; long term clinical evaluation; radiographically acceptable implants; single tooth; very low speed drilling; young adults; Bonding; Bones; Dentistry; Implants; Instruments; Surgery; Teeth; Titanium; Torque; Yarn;