• DocumentCode
    235894
  • Title

    Short localization in a multi chip BGA package

  • Author

    Gaudestad, J. ; Orozco, Alvaro ; Kimball, Mark ; Gopinadhan, Kalon ; Venkatesan, Thirumalai

  • Author_Institution
    Neocera LLC, Beltsville, MD, USA
  • fYear
    2014
  • fDate
    June 30 2014-July 4 2014
  • Firstpage
    74
  • Lastpage
    77
  • Abstract
    Magnetic Current Imaging (MCI) has been used for more than a decade to localize shorts and leakages in packages non-destructively. Now that packages are becoming more complex with multiple dies inside the same package, MCI is showing its effectiveness in localizing these complicated shorts non-destructively when the Failure Analysis (FA) engineer does not know from Automated Test Equipment (ATE) if the fault location is in the die or package or which die. We show in this paper that the FA lab can be simplified by the introduction of MCI as a one stop Fault Isolation (FI) tool for all shorts and leakages.
  • Keywords
    automatic test equipment; ball grid arrays; multichip modules; packaging; ATE; MCI; automated test equipment; failure analysis engineer; fault isolation tool; fault location; magnetic current imaging; multi chip BGA package; short localization; Decision support systems; Failure analysis; Integrated circuits;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Physical and Failure Analysis of Integrated Circuits (IPFA), 2014 IEEE 21st International Symposium on the
  • Conference_Location
    Marina Bay Sands
  • ISSN
    1946-1542
  • Print_ISBN
    978-1-4799-3931-2
  • Type

    conf

  • DOI
    10.1109/IPFA.2014.6898191
  • Filename
    6898191