DocumentCode
236072
Title
Building-up the DC voltage scale for sources and meters
Author
Early, Murray D. ; Christian, Laurie A. ; Lawson, Tim B.
Author_Institution
Meas. Stand. Lab. of New Zealand (MSL), Lower Hutt, New Zealand
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
138
Lastpage
139
Abstract
Previous work has shown that an automated build-up method, called the Reference Step Method (RSM), can measure the gain ratios of a dc voltage source with an uncertainty of 0.2 μV/V up to 1000 V. We have extended this method to also establish the gain ratio of the digital voltmeter (DVM) used in the build-up method. This only requires a few additional measurements so that the gain ratios of the source and meter can be measured simultaneously. Initial measurements suggest that comparable uncertainties can also be achieved for the DVM.
Keywords
digital voltmeters; electric current measurement; gain measurement; voltage measurement; DC voltage source scale; DVM; RSM; build-up method; digital voltmeter; gain ratio measurement; reference step method; Gain measurement; Linearity; Measurement uncertainty; Meter reading; Standards; Uncertainty; Voltage measurement; dc build-up; dc range calibration; dc voltage ratio; dc voltage scale; measurement techniques;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location
Rio de Janeiro
ISSN
0589-1485
Print_ISBN
978-1-4799-5205-2
Type
conf
DOI
10.1109/CPEM.2014.6898297
Filename
6898297
Link To Document