• DocumentCode
    236177
  • Title

    AC characterizations of current shunts

  • Author

    Kon, S. ; Yamada, Tomoaki

  • Author_Institution
    Nat. Metrol. Inst. of Japan, AIST, Tsukuba, Japan
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    244
  • Lastpage
    245
  • Abstract
    The dependence of cage-type AC shunt resistance and phase angle on frequency and input current is examined in this paper, for shunts with different current ratings. The AC resistance of shunts remains constant for up to 1 kHz, but the phase angle changes proportionally to the frequency. The results of current dependencies on AC resistance are consistent with each other within measurement uncertainties between 1 A and 10 A. The phase angle does not depend on the current, for values up to 10 A. The effects of current heating of shunts are also evaluated. The thermal time constant of shunts is found to be approximately 200 s and does not depend on the shunts and the input current frequency.
  • Keywords
    calibration; electric current measurement; electric resistance measurement; measurement uncertainty; cage-type AC shunt resistance; calibration; current heating; measurement uncertainty; phase angle; thermal time constant; Calibration; Current measurement; Current transformers; Measurement uncertainty; Resistance; Resistors; Standards; AC characteristic; calibration; current; phase angle; shunt resistor;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898350
  • Filename