    A 10 a high-precision DC current source with stability better than 0.1 ppm for evaluating high-current meter

  • Author

    Nong Wang ; Zhengkun Li ; Qing He ; Zhonghua Zhang ; Bing Han ; Yunfeng Lu

  • Author_Institution
    Harbin Inst. of Technol., Harbin, China
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    248
  • Lastpage
    249
  • Abstract
    The principle and structure of a 10 A high stable DC current source is described. Factors determining the current stability are analyzed and the crucial components including the voltage reference, sample resistor, error amplifier and regulator are elaborately selected to guarantee the current stability. Reasons for oscillation and frequency compensation methods are discussed. The best measurement results show that the relative drift and the relative standard deviation of the current in one hour are about 5.9×10-8 and 9.3×10-8 respectively, and the same characteristics in 10 minutes are about 8.2×10-9 and 4.9×10-8 respectively.
  • Keywords
    amplifiers; compensation; constant current sources; electric current measurement; measurement standards; oscillations; resistors; DC current source; current 10 A; current stability determination; error amplifier; frequency compensation method; oscillation; regulator; relative drift; relative standard deviation; sample resistor; voltage reference; Circuit stability; Oscillators; Regulators; Resistors; Stability criteria; Temperature measurement; Current source; current supply; high-current meter; standard current; voltage reference;
  • fLanguage