• DocumentCode
    236229
  • Title

    Results of the SIM.EM-K5 key comparison of 50/60 Hz power

  • Author

    Carranza, R. ; Campos, Sergio ; Castruita, A. ; Nelson, T. ; Ribeiro, Alejandro ; So, Eddy ; Di Lillo, L. ; Spaggiari, A. ; Slomovitz, Daniel ; Izquierdo, David ; Faverio, Carlos ; Postigo, H. ; Sanchez, Hector Eloys ; Gonzalez, Jose ; Porras, G.

  • Author_Institution
    Centro Nac. de Metrol. Mexico, Mexico City, Mexico
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    302
  • Lastpage
    303
  • Abstract
    From years 2010 to 2012, a key comparison of power standards at 50/60 Hz was conducted in the SIM region. The comparison included measurements of active and reactive power at three frequencies, aiming at providing support to high accuracy measurement needs of reactive power. This paper presents the results of the SIM.EM-K5 comparison and the assessment of the link between this comparison and the CCEM-K5 key comparison on 50/60 Hz power completed in 2001.
  • Keywords
    measurement standards; power measurement; reactive power; CCEM- K5 key comparison; SIM.EM-K5 key comparison; active power measurement; frequency 50 Hz; frequency 60 Hz; power standard; reactive power measurement; Atmospheric measurements; Frequency measurement; Laboratories; Particle measurements; Power measurement; Reactive power; Standards; Key comparison; linear regression fitting; power measurement standards; reproducibility; uncertainty;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898379
  • Filename
    6898379