Abstract :
This paper describes an experimental evaluation of a high precision voltage harmonic analyzer at power frequency under square waveform. The error and uncertainty of the signal generator were calculated to use it as a harmonic reference standard at UTE (Uruguayan designated National Metrology Institute).
Keywords :
calibration; measurement standards; signal generators; voltage measurement; UTE; Uruguayan designated National Metrology Institute; calibration; harmonic measurement system; harmonic reference standard; high precision voltage harmonic analyzer; power frequency; signal generator; square waveform; Algorithm design and analysis; Distortion measurement; Harmonic analysis; Oscilloscopes; Standards; Uncertainty; Voltage measurement; calibration; distortion; energy; error; harmonic; high precision; measurements; power;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
Print_ISBN :
978-1-4799-5205-2
DOI :
10.1109/CPEM.2014.6898383