Abstract :
Uncertainty analysis of a very simple sampling phase meter based on four parameter sine wave fitting is presented in this paper. An uncertainty of a sample time and a measured voltage is assigned to every sampled point and a total uncertainty of a phase difference is calculated by means of the Monte Carlo method. Results show the total uncertainty is lower than 0.5 millidegree for selected digitizer. A noise of the measured signal or the digitizer is the largest contribution to the total uncertainty.
Keywords :
Monte Carlo methods; electric noise measurement; measurement uncertainty; phase meters; phase noise; voltage measurement; Monte Carlo method; noncoherent sampling phase meter uncertainty analysis; parameter sine wave fitting; phase difference uncertainty; signal noise measurement; voltage measurement; Barium; Generators; Measurement uncertainty; Monte Carlo methods; Phase measurement; Uncertainty; Voltage measurement; Monte Carlo; measurement uncertainty; phase difference; sine wave fitting;