Title :
Linearity analysis of a calorimetric thermal voltage converter for RF-DC transfer difference up to 1 GHz
Author :
Yueyan Shan ; Yu Song Meng ; Filipski, Piotr S.
Author_Institution :
Nat. Metrol. Centre, Agency for Sci., Technol. & Res. (A*STAR), Singapore, Singapore
Abstract :
Linearity analysis of a calorimetric thermal voltage converter (CTVC) designed by the National Research Council of Canada for RF-DC transfer difference up to 1 GHz is presented in this paper. At higher frequencies, the CTVC is evaluated in terms of the calibration factor of a RF power sensor and the reflection coefficients at its Type-N connector. Good performance has been observed which indicates that CTVC could be a potential candidate for calibrating RF power sensors in terms of its RF-DC transfer difference.
Keywords :
calibration; calorimetry; electric connectors; electric sensing devices; transfer standards; voltage measurement; CTVC; RF power sensor calibration; RF-DC transfer difference; Type-N connector; calorimetric thermal voltage converter; frequency 1 GHz; linearity analysis; reflection coefficients; Calibration; Connectors; Linearity; Power measurement; Radio frequency; Reflection coefficient; Standards; CTVC; RF-DC transfer difference; linearity; mathematical modeling;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
Print_ISBN :
978-1-4799-5205-2
DOI :
10.1109/CPEM.2014.6898401