DocumentCode
236278
Title
Development of a type-N coaxial microcalorimeter for RF and microwave power standards at KRISS
Author
Jae-Yong Kwon ; Tae-Weon Kang ; Jeong-Hwan Kim ; No-Weon Kang
Author_Institution
A Center for Electromagn. Wave, Korea Res. Inst. of Stand. & Sci. (KRISS), Daejeon, South Korea
fYear
2014
fDate
24-29 Aug. 2014
Firstpage
350
Lastpage
351
Abstract
Sets of coaxial and waveguide microcalorimeters have been successfully used as primary power standards in RF and microwave frequency ranges at KRISS. Recently, we have developed a type-N coaxial microcalorimeter to replace a legacy microcalorimeter that had been in use for over two decades. Design of some core parts and implementation of the microcalorimeter are described. Preliminary uncorrected effective efficiencies of type-N coaxial reference standards are shown, and future plan for system evaluation is briefly discussed.
Keywords
calorimeters; coaxial cables; measurement standards; microwave measurement; power measurement; power transmission lines; KRISS; RF range; microwave frequency range; power measurement; primary power standards; type-N coaxial microcalorimeter; Calibration; Connectors; Microwave measurement; Power measurement; Radio frequency; Standards; Transmission line measurements; Adiabatic lines; calibration; coaxial transmission lines; power measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location
Rio de Janeiro
ISSN
0589-1485
Print_ISBN
978-1-4799-5205-2
Type
conf
DOI
10.1109/CPEM.2014.6898403
Filename
6898403
Link To Document