Title :
Using digital multimeters in place of analog null meters for metrological applications
Author :
Faulkner, Neil ; Gust, Jeff
Author_Institution :
Fluke Calibration, Everett, WA, USA
Abstract :
Historically, analog null meters have been used to determine zero voltage conditions in metrological applications. When digital multimeters (DMMs) became available with resolution comparable to null meters, they were adopted quickly, and analog null meters were set aside. Depending on the circuit and the DMM, significant measurement errors can be introduced. This paper discusses in detail investigations associated with one particular model of precision DMM when used as a null detector and provides measurement configuration details to minimize errors so that the DMM can out-perform analog null meters.
Keywords :
digital multimeters; measurement errors; minimisation; voltage measurement; DMM; analog null meters; digital multimeters; measurement error minimization; metrological applications; zero voltage conditions determination; Bridge circuits; Calibration; Detectors; Noise; Resistance; Standards; Voltage measurement; measurement techniques; null detectors; null meters; precision measurements;
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
Print_ISBN :
978-1-4799-5205-2
DOI :
10.1109/CPEM.2014.6898476