• DocumentCode
    236442
  • Title

    AC-DC transfer measurements in the mV-range using discrete micropotentiometers

  • Author

    Geronymo, Gean ; Ribeiro-Silva, C.I. ; Souza, R.M. ; Klonz, M.

  • Author_Institution
    Inst. Nac. de Metrol., Qualidade e Tecnol., Rio de Janeiro, Brazil
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    514
  • Lastpage
    515
  • Abstract
    This paper describes the new primary standard for the ac-dc low voltage transfer at Inmetro, based on micropotentiometers with PMJTCs and commercial current shunts. The design of the new micropotentiometers is presented, followed by the build-down of the voltage scale into the mV-ranges and the uncertainty analysis. Finally, the results of an unofficial interlaboratory comparison between Inmetro and PTB, at 20 mV, are presented and discussed.
  • Keywords
    electric current measurement; measurement uncertainty; potentiometers; transfer standards; voltage measurement; AC-DC low voltage transfer standard; AC-DC transfer measurement; Inmetro; PMJTC; PTB; current shunt; discrete micropotentiometer; measurement uncertainty analysis; voltage 20 mV; Calibration; Resistors; Standards; Temperature measurement; Thermal resistance; Uncertainty; AC-DC voltage difference; electrical metrology; micropotentiometer; milivolt calibration; thermoconverters;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898485
  • Filename
    6898485