• DocumentCode
    236488
  • Title

    Two calibration methods for inductive voltage divider

  • Author

    Jian Feng ; Lei Lai ; Leibing Shi ; Yang Pan

  • Author_Institution
    Shanghai Inst. of Meas. & Testing Technol., Shanghai, China
  • fYear
    2014
  • fDate
    24-29 Aug. 2014
  • Firstpage
    560
  • Lastpage
    561
  • Abstract
    Incremental method and normal-reversed reference voltage method used for the calibration of inductive voltage dividers(IVDs) are introduced. Capacitive leakage due to shielding screens of reference transformer and detection transformer is compensated by electronic method. Special shielding structure of reference transformer and detection transformer are presented.
  • Keywords
    calibration; reference circuits; shielding; transformers; voltage dividers; calibration; capacitive leakage; detection transformer; electronic method; incremental method; inductive voltage dividers; normal-reversed reference voltage method; reference transformer; shielding structure; Calibration; Impedance; Magnetic cores; Magnetic noise; Magnetic shielding; Voltage measurement; Windings; Detection transformer; incremental; inductive voltage divider; normal and reversed; reference transformer;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
  • Conference_Location
    Rio de Janeiro
  • ISSN
    0589-1485
  • Print_ISBN
    978-1-4799-5205-2
  • Type

    conf

  • DOI
    10.1109/CPEM.2014.6898508
  • Filename
    6898508