DocumentCode :
236488
Title :
Two calibration methods for inductive voltage divider
Author :
Jian Feng ; Lei Lai ; Leibing Shi ; Yang Pan
Author_Institution :
Shanghai Inst. of Meas. & Testing Technol., Shanghai, China
fYear :
2014
fDate :
24-29 Aug. 2014
Firstpage :
560
Lastpage :
561
Abstract :
Incremental method and normal-reversed reference voltage method used for the calibration of inductive voltage dividers(IVDs) are introduced. Capacitive leakage due to shielding screens of reference transformer and detection transformer is compensated by electronic method. Special shielding structure of reference transformer and detection transformer are presented.
Keywords :
calibration; reference circuits; shielding; transformers; voltage dividers; calibration; capacitive leakage; detection transformer; electronic method; incremental method; inductive voltage dividers; normal-reversed reference voltage method; reference transformer; shielding structure; Calibration; Impedance; Magnetic cores; Magnetic noise; Magnetic shielding; Voltage measurement; Windings; Detection transformer; incremental; inductive voltage divider; normal and reversed; reference transformer;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
ISSN :
0589-1485
Print_ISBN :
978-1-4799-5205-2
Type :
conf
DOI :
10.1109/CPEM.2014.6898508
Filename :
6898508
Link To Document :
بازگشت