Abstract :
This paper describes the detailed analysis employed in the development of the S-parameter standard for 2.92 mm coaxial lines at the National Metrology Institute of Japan (NMIJ). An important part is the method of analyzing connector effects in measuring the dimensions of a primary standard and applying a theoretical model. We used an adapter or air line to simulate effects of the connections when measuring its dimensions. The major uncertainties of the dimensional measurements were the deformations caused by the connections. To relate the dimensional deformations to the S-parameters of the standard, cascade model was better than uniform model.
Keywords :
S-parameters; coaxial cables; deformation; electric connectors; electric variables measurement; electromagnetic wave scattering; measurement standards; measurement uncertainty; spatial variables measurement; National Metrology Institute of Japan; S-parameter standard; adapter; air line; cascade model; coaxial lines; connector effect; dimensional deformation; dimensional measurement uncertainty; primary standard; size 2.92 mm; Atmospheric modeling; Connectors; Measurement uncertainty; Scattering parameters; Standards; Transmission line measurements; Uncertainty; Measurement; measurement standards; measurement uncertainty; scattering parameters; transmission lines;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Precision Electromagnetic Measurements (CPEM 2014), 2014 Conference on
Conference_Location :
Rio de Janeiro
ISSN :
0589-1485
Print_ISBN :
978-1-4799-5205-2
Type :
conf
DOI :
10.1109/CPEM.2014.6898518
Filename :
6898518
Link To Document :
بازگشت